AC Froze Up and the House Kept Warming in Holly Springs
Holly Springs · September 2026 · Mario · From our service records
What the customer reported
A Holly Springs homeowner reported that the AC thermostat temperature was rising, and the unit was found frozen at the initial appointment, so a return visit was scheduled to check the frozen coil.
What we found and did
Mario found that the second-floor zone two damper in the zoning system was failing to open when called upon, which severely restricted airflow and caused the coil to freeze over. He first called for cooling at both thermostats and tested the unit, observing no signs of a system restriction or low pressures, before checking the zoning system and pinpointing the failing damper. With the homeowner's approval, Mario replaced the damper, and the homeowner also signed up for a service agreement.
Result
The system was cooling properly at the end of the visit.