What Does a Four-System Heating Tune-Up Include in Raleigh?
Raleigh · November 2026 · Nick, Matthew & Dexter · From our service records
What we found and did
During the inspection of the 1st floor gas pack unit, Matthew found some corrosion on the heat shield, flame sensor and flame ignitor, as well as a weak inducer motor capacitor. On the three gas furnaces, he inspected and cleaned the flame sensors, tested the flame ignitors, the amp draw to the blower motors and inducer motors, the run capacitor, the pressure switches and the gas manifold pressures, and took a temperature split between the supply and return duct work. On the heat pump, he tested the amp draw to the outdoor compressor and fan motor, the dual run capacitor, refrigerant pressures and the contactor, tested the blower motor amp draw at the attic air handler, and cleaned the condensate P trap. He also strongly suggested surge protection for the 2nd floor heat pump (one for the air handler, one for the condenser) and one for the 1st floor addition furnace in the crawl space, with estimates to be sent by email.
Result
All four systems were operational when the technicians left.