AC Shutting Off and Restarting on Its Own in Lillington
Lillington · May 2026 · Bernard, Manny & Mario · From our service records
What the customer reported
A Lillington homeowner reported the system would shut off periodically and eventually restart on its own. The homeowner had cleaned the EZ-Trap and removed some blockage before the visit.
What we found and did
Bernard found water in the secondary safety switch at the air handler in the crawl space, and a drain test showed a blockage in the condensate line. He removed the residual water, confirmed the EZ-Trap was clear, and poured one quart of water through the condensate line, which drained improperly. Bernard then flushed the drain line with a water hose until adequate pressure cleared the blockage.
Result
After retesting the drain line with an additional quart of water mixed with cleaner and resetting the thermostat, the system was verified to be operating normally.