AC Stopped Turning On Overnight in Zebulon
Zebulon · August 2026 · Manny · From our service records

What the customer reported
A Zebulon homeowner reported the unit was not turning on, a problem that started the night before on a system over 10 years old.
What we found and did
Manny found the secondary auxiliary drain pan filled with water, which had tripped the safety float switch and shut the system down. He cleared the primary condensate drain line, verified proper drainage, and reset the system. While checking the downstairs system, he recorded low subcooling of 4.2°F and low superheat of 4.9°F, and noted active moisture and puddles in the crawlspace coming from the downstairs air handler cabinet, where the low refrigerant/operating parameters were causing the unit and suction lines to sweat heavily. He also confirmed the upstairs system's refrigerant pressures, subcooling, and superheat were dialed in to manufacturer specifications.
Result
After the reset, the upstairs system was fully operational with a healthy 20°F temperature split (82°F return / 62°F supply), and the downstairs system showed a 19°F split (76°F return / 57°F supply).