Year-Old Heat Pump Not Cooling in Hillsborough
Hillsborough · March 2026 · Mario & Dexter · From our service records
What the customer reported
A Hillsborough homeowner reported that their 1 year old unit, originally installed by the company, was not cooling.
What we found and did
Mario found the heat pump was not coming on because the defrost board was not sending voltage through the low pressure switch. He started by making a call for cool at the thermostat and checking the air handler, then moved to the heat pump on the left side of the building, where he confirmed the high pressure switch was receiving and passing 24v. The defrost board started passing voltage after 15 minutes of diagnostics, and Mario recommended having the defrost board replaced, with the board ordered separately since the visit ran after 5pm.
Result
The system was operating and cooling when Mario left, with the defrost board replacement recommended.