AC Repair
October 2026 · Mebane · Bernard
AC Running but No Air from Vents in Mebane
What the customer reported
A Mebane homeowner's family reported that when the system was switched to cooling mode, the outdoor unit would come on, but there was no airflow coming through the supply vents.
What we found and did
Bernard found that the indoor blower motor had mechanically failed and needs replacement. He made a call for cooling at the thermostat and verified the compressor and outdoor fan motor were operating properly, but the indoor blower motor would not start. He confirmed the motor was receiving the proper 24V call and the correct high voltage (240V across both legs and 120V on each individual leg), and that the blower wheel was free-spinning without restriction. He told the homeowner he would contact the office in the morning to verify part availability and follow up on scheduling the repair.