Apartment AC Not Working in Late August in Chapel Hill
Chapel Hill · August 2026 · Mario · From our service records

What the customer reported
The leasing office reported cooling issues at an apartment in the 27516 area of Chapel Hill, noting the unit was not working and that the problem was suspected to be in the fans.
What we found and did
Mario found two major issues: the blower control board was getting stuck closed and continuously sending voltage to the blower, and the system was low on R-22 refrigerant. He initiated a call for cooling at the thermostat, checked system operations, and conducted a leak search that located leaks at both the evaporator coil and the liquid service valve. Because the unit was from 1996 (30 years old), was in very rough condition, and had other components in poor shape, Mario strongly advised complete unit replacement over attempting repairs.